✨ New Arrivals Just Dropped!Explore

HomeStore
Constant Wattage LED Emergency Backup Driver, Includes LED module, 12 Watt Output, California Compliant
Constant Wattage LED Emergency Backup Driver, Includes LED module, 12 Watt Output, California Compliant
- Drives dedicated LED load (included) at 12W for a minimum of 90 minutes
- Short circuit overload and open load protection
- Suitable for dry and damp locations
- Evaluated to UL 924 standards
- 2 -in- 1 LED test switch and indicator light included
- UL Listed
Electrical Specifications
- Input voltage range: 120~277Vac ± 10%
- Frequency: 50/60Hz
- Power factor: >0.9 under 120~277Vac input
- Max input current: 50mA @120V, 35mA @240V, and 30mA @277V
- THD: <20% under 120~277Vac input
- Output voltage: 20–60Vdc Class 2 compliant (Remarks: the output power is valid for output voltage ≤58V; above that power will drop)
- Output current: 600mA @ 20Vdc, 206mA @ 58Vdc
- Output power: 12W (constant)
- Turn-on Delay Time: <1s
- Overshoot: <10%
- Ripple & Noise (pk–pk): <10%
- Withstand voltage: Input to output, 2800Vdc, 2mA
- Leakage current: Maximum 0.5mA at 277Vac, 60Hz input
- Emergency Operation: 90 minutes
- Battery: High-temperature, maintenance-free, LiFePO4 battery, 9.6Vdc, 3 cell
- Recharge Time: 24 hours
- Battery Charging Current: 307mA
Protection
- Over voltage protection: Hiccup mode. Protection will trigger when load voltage exceeds specified output voltage and will auto recover after the fault mode is removed.
- Over current protection: Hiccup mode. Protection will trigger when load current exceeds specified output current and will auto recover after the fault mode is removed.
- Short circuit protection: Hiccup mode. Protection will trigger when short circuit and will auto recover after the fault mode is removed.
- Over temperature protection: Protection will trigger when driver overheats and auto-recovery when cooled down.
$66.47
Original: $221.58
-70%Constant Wattage LED Emergency Backup Driver, Includes LED module, 12 Watt Output, California Compliant—
$221.58
$66.47Constant Wattage LED Emergency Backup Driver, Includes LED module, 12 Watt Output, California Compliant
- Drives dedicated LED load (included) at 12W for a minimum of 90 minutes
- Short circuit overload and open load protection
- Suitable for dry and damp locations
- Evaluated to UL 924 standards
- 2 -in- 1 LED test switch and indicator light included
- UL Listed
Electrical Specifications
- Input voltage range: 120~277Vac ± 10%
- Frequency: 50/60Hz
- Power factor: >0.9 under 120~277Vac input
- Max input current: 50mA @120V, 35mA @240V, and 30mA @277V
- THD: <20% under 120~277Vac input
- Output voltage: 20–60Vdc Class 2 compliant (Remarks: the output power is valid for output voltage ≤58V; above that power will drop)
- Output current: 600mA @ 20Vdc, 206mA @ 58Vdc
- Output power: 12W (constant)
- Turn-on Delay Time: <1s
- Overshoot: <10%
- Ripple & Noise (pk–pk): <10%
- Withstand voltage: Input to output, 2800Vdc, 2mA
- Leakage current: Maximum 0.5mA at 277Vac, 60Hz input
- Emergency Operation: 90 minutes
- Battery: High-temperature, maintenance-free, LiFePO4 battery, 9.6Vdc, 3 cell
- Recharge Time: 24 hours
- Battery Charging Current: 307mA
Protection
- Over voltage protection: Hiccup mode. Protection will trigger when load voltage exceeds specified output voltage and will auto recover after the fault mode is removed.
- Over current protection: Hiccup mode. Protection will trigger when load current exceeds specified output current and will auto recover after the fault mode is removed.
- Short circuit protection: Hiccup mode. Protection will trigger when short circuit and will auto recover after the fault mode is removed.
- Over temperature protection: Protection will trigger when driver overheats and auto-recovery when cooled down.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
- Drives dedicated LED load (included) at 12W for a minimum of 90 minutes
- Short circuit overload and open load protection
- Suitable for dry and damp locations
- Evaluated to UL 924 standards
- 2 -in- 1 LED test switch and indicator light included
- UL Listed
Electrical Specifications
- Input voltage range: 120~277Vac ± 10%
- Frequency: 50/60Hz
- Power factor: >0.9 under 120~277Vac input
- Max input current: 50mA @120V, 35mA @240V, and 30mA @277V
- THD: <20% under 120~277Vac input
- Output voltage: 20–60Vdc Class 2 compliant (Remarks: the output power is valid for output voltage ≤58V; above that power will drop)
- Output current: 600mA @ 20Vdc, 206mA @ 58Vdc
- Output power: 12W (constant)
- Turn-on Delay Time: <1s
- Overshoot: <10%
- Ripple & Noise (pk–pk): <10%
- Withstand voltage: Input to output, 2800Vdc, 2mA
- Leakage current: Maximum 0.5mA at 277Vac, 60Hz input
- Emergency Operation: 90 minutes
- Battery: High-temperature, maintenance-free, LiFePO4 battery, 9.6Vdc, 3 cell
- Recharge Time: 24 hours
- Battery Charging Current: 307mA
Protection
- Over voltage protection: Hiccup mode. Protection will trigger when load voltage exceeds specified output voltage and will auto recover after the fault mode is removed.
- Over current protection: Hiccup mode. Protection will trigger when load current exceeds specified output current and will auto recover after the fault mode is removed.
- Short circuit protection: Hiccup mode. Protection will trigger when short circuit and will auto recover after the fault mode is removed.
- Over temperature protection: Protection will trigger when driver overheats and auto-recovery when cooled down.